APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 21002 Issued:1998-08-18
Revised:2012-07-26
Style 21002 Multiple conductor with extruded insulation.

Rating105 deg C, 300 Vac, 600 Vac, Cable flame.
InsulationLabeled or complying with manufacturer's AWM Procedure.
AssemblyTwo or more singles, twisted pairs of groups of twisted singles twisted together or singles or groups of singles may be laid parallel to form flat, oval or round cable. Lay not specified. Barrier layer and/or fillers optional. Manufacturer shall maintain a complete description of each assembly. May use same or mixed AWG size.
ShieldOptional.
CoveringOptional.
BraidOptional.
JacketTPE
major dia. in inches of 0.700 or less30 mils min average
0.701-1.000 dia45 avg
1.001-1.500 dia60 avg
1.501-2.500 dia80 avg
2.501-4.000 dia110 avg
4.001 dia and larger140 avg
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring or external inter-connection of electronic equipment or X-ray equipment).

UL and the UL Logo are trademarks of UL LLC © 2019