iq.ul.com
CLICK TO CONTINUEView additional material information including performance and processing data The information presented on the UL Prospector datasheet was acquired by UL Prospector from the producer of the material. UL Prospector makes substantial efforts to assure the accuracy of this data. However, UL Prospector assumes no responsibility for the data values and strongly encourages that upon final material selection, data points are validated with the material supplier.
Component - PlasticsE41938
Guide Information
E I DUPONT DE NEMOURS & CO INC
ENGINEERING POLYMERS, CHESTNUT RUN PLAZA, PO BOX 80713, WILMINGTON DE 19880-0713
FR50(+)(f1)
Polyamide 66 (PA66), flame retardant, glass reinforced "Zytel", furnished as pellets

Color
Min. Thk
(mm)
Flame
Class

HWI

HAI
RTI
Elec
RTI
Imp
RTI
Str
ALL0.35V-0-----
0.75V-000130105105
NC, BK1.5V-0, 5VA00130115115
3.0V-0, 5VA00130115120
Comparative Tracking Index (CTI):2Inclined Plane Tracking (IPT) kV:-
Dielectric Strength (kV/mm):25Volume Resistivity (10x ohm-cm):11
High-Voltage Arc Tracking Rate (HVTR):1High Volt, Low Current Arc Resis (D495):6
Dimensional Stability (%):-
(+) - Virgin and regrind up to 50% by weight inclusive, have the same basic material characteristics.
(f1) - Suitable for outdoor use with respect to exposure to Ultraviolet Light, Water Exposure and Immersion in accordance with UL 746C.
NOTE - (1) Material designations that are color pigmented may be followed by suffix letters and numbers. (2) Material designations may be prefixed by "ZYT" for Zytel or "MIN" for Minlon or "DEL" for Delrin or "CRA" for Crastin or "RYN" for Rynite or "ETPV" for ETPV or "SOR" for Sorona grades.
ANSI/UL 94 small-scale test data does not pertain to building materials, furnishings and related contents. ANSI/UL 94 small-scale test data is intended solely for determining the flammability of plastic materials used in the components and parts of end-product devices and appliances, where the acceptability of the combination is determined by UL.
Report Date:1996-08-20© 2019 UL LLC
Last Revised:2018-09-27

IEC and ISO Test Methods
Test NameTest MethodUnitsThk (mm)Value
FlammabilityIEC 60695-11-10, IEC 60695-11-20Class (color)0.35V-0 (ALL)
0.75V-0 (ALL)
1.5V-0, 5VA (NC, BK)
3.0V-0, 5VA (NC, BK)
Glow-Wire Flammability (GWFI)IEC 60695-2-12°C0.75960
1.5960
3.0960
Glow-Wire Ignition (GWIT)IEC 60695-2-13°C0.75900
1.5900
3.0930
IEC Comparative Tracking IndexIEC 60112Volts (Max)--
IEC Ball PressureIEC 60695-10-2°C-240
ISO Heat Deflection (1.80 MPa)ISO 75-2°C--
ISO Tensile StrengthISO 527-2MPa--
ISO Flexural StrengthISO 178MPa--
ISO Tensile ImpactISO 8256kJ/m2--
ISO Izod ImpactISO 180kJ/m2--
ISO Charpy ImpactISO 179-2kJ/m2--