Rating | 200 deg C, 150 Vac, Horizontal flame, Oil Res 60 deg C or 80 deg C (optional), Gasoline Resistant |
|
Conductor | 32 AWG - 6 AWG solid or stranded, silver plated or nickel coated copper, andnickel conductor, silver plated zirconium copper alloy, Insulationsilver plated cadmium chrome copper alloy, silver plated cadmium bronze copper alloy, or silver plated copper-clad steel. |
|
Insulation | FEP or PTFE, TFE |
| 32-10 AWG conductor size | 9 mils min average | 8 mils min at any point |
| 9-6 AWG | 20 avg | 18 min |
| If tinned copper conductors are used, FEP should be employed. |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | In back panel areas of electronic equipment, such as electronic computers and business machines, where not subjected to movement or mechanical damage. "300 peak Volts for Electronic Use Only". "Suitable for immersion in gasoline; gasoline vapor; and 60 deg C or 80 deg C in oil". |
|