APPLIANCE WIRING MATERIAL
Subj.758 Section 1 Page 10110 Issued:1991-10-17
Revised:2012-10-18
Style 10110 Single conductor with extruded insulation

Rating105 deg C, Voltage Not Specified, Horizontal flame.
Conductor36 AWG - 6 AWG, solid or stranded. silver plated or nickel coated copper, nickel conductor, silver plated zirconium copper alloy, silver plated cadmium chrome copper alloy, silver plated cadmium bronze copper alloy, or silver plated copper-clad steel, In addition, tinned copper conductors may be employed.
InsulationExtruded PFA.
Conductor SizeMinimum Average ThicknessMinimum Thickness At Any Point
36-20 AWG5.5 mils5 mils
19-16 AWG8 mils7 mils
15-10 AWG13 mils12 mils
9-6 AWG20 mils18 mils
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseIn back panel areas of electronic equipment, such as electronic computers and business machines, where not subjected to movement or mechanical damage.

UL and the UL Logo are trademarks of UL LLC © 2024