Rating | 150 deg C, 150 Vac, Horizontal Flame. |
|
Conductor | 40 AWG - 6 AWG, Solid or Stranded Round. |
|
Insulation | Extruded ETFE |
| Conductor AWG Size | mils minimum average | mils minimum at any point |
| 40-15 | 4 | 3 |
| 14-10 | 8 | 7 |
| 9-6 | 15 | 13 |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | Internal wiring of electronic equipment, where not subjected to movement of mechanical damage. May also be used for further processing in cables. |
|