Subj.758 Section 1 Page 1056 Issued:1959-05-01
Revised:2013-11-22
Style 1056 Single conductor with extruded insulation

Rating105 deg C, 600 Vac, Horizontal flame. Optional - 60 deg C or 80 deg C Oil.
Conductor20 AWG - 10 AWG, stranded.
InsulationExtruded PVC, 60 mils minimum average thickness, 54 mils minimum thickness at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal Wiring of Indoor or Outdoor Refrigerating Equipment.