Rating | 200 deg C, 300 Vac, Horizontal Flame, Oil Resistant 80 deg C (optional). |
|
Insulation | Labeled or complying with manufacturer's AWM Procedure and having a minimum rating of 200 C and 300 volts. The designations of all styles of individual conductors used in making up the cable assembly shall be available. |
|
Shield | Optional. |
|
Jacket | Extruded FEP, 20 mils minimum average thickness, 16 mils minimum thickness at any point. |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | Internal wiring of appliances or electronic equipment. In addition, the tag may also indicate the following: 600 volts peak -- For Electronic Use Only. |
|