Rating | 60 deg C, 30 Vac, Horizontal flame. |
|
Conductor | 40 AWG min., material not specified. |
|
Insulation | Extruded FEP or Extruded FRPE or Extruded PE or Extruded PFA or Extruded PTFE, Extruded TFE, solid or cellular, 5.0 mils min at any point, 100 mils max. Irradiation optional. |
|
Covering | Optional. Non-extruded Polyester tape, 0.2 mil min at any point applied with 50 percent overlap and heat sealed. |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | As insulated singles for use in jacketed cable. For use in Class 2 circuits of electronic equipment. |
|