APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 20261 Issued:1983-04-18
Revised:2012-01-12
Style 20261 Multiple-conductor cable using non-integral jacket

Rating80 deg C, 30 Vac, Horizontal flame.
Conductor40 AWG min. Material not specified.
InsulationFEP or PE or XLPE, 2 mils min average, 2 mils min at any point, 100 mils max, solid or cellular. Irradiation optional. Barrier layer and/or fillers optional.
AssemblyTwo through ten conductors
ShieldOptional.
Covering2 mils min at any point, extruded PVC, Polyamide, (Optional) or Polyester or lacquered braid.
JacketPOLYAMIDE or POLYESTER or PVC, 2 mils min average - Optional, same as covering.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal Wiring of Class 2 Circuits in Electronic Equipment.

UL and the UL Logo are trademarks of UL LLC © 2024