Style 20368 Multiple-conductor cable using non-integral jacket.

Rating200 deg C, 300 Vac, Cable flame, Optional - 80 deg C Oil.
InsulationLabeled or complying with manufacturer's AWM procedure and having a minimum rating of 200 deg C and 300 volts. The designations of all styles of individual conductors used in making up the cable assembly shall be available.
ShieldOptional.
AssemblyTwo or more individually insulated conductors or groups of insulated conductors cabled together. All conductors in any group twisted together. If more than one group is used, groups shall also be twisted together. The length of lay of the twisted conductors or groups is not specified. A barrier layer, if employed, may be of fibrous wrap serving, or braid; paper; nylon; oriented polyethylene terephthalate; or thermoplastic-type wrap. Such a barrier layer would serve to protect the cable during further processing and would be applied immediately over the twisted assembly of individual conductors or groups of conductors.
JacketExtruded FEP
dia of the cable under jacket in inches
0.425 or less25 mils min average20 mils minimum at any point
0.426-0.700 dia30 avg24 min
0.701-1.500 dia45 avg36 min
1.501-2.500 dia60 avg48 min
2.501 dia and larger80 avg64 min
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseExternal interconnection or internal wiring of appliances or electronic equipment. In addition, the tag may also indicate the following: Suitable for immersion in oil at 80 deg C, or 600 volts peak - For Electronic Use Only.