APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 20369 Issued:1985-01-25
Revised:2022-09-16
Style 20369 Multiple-conductor Cable using non-integral Jacket

Rating200 deg C, 600 Vac, Cable flame, Oil Resistant 80 deg C (optional).
InsulationLabeled or complying with manufacturer's AWM procedure.
AssemblyTwo or more individually insulated conductors or groups of insulated conductors cabled together. All conductors in any group twisted together. If more than one group is used, groups shall also be twisted together. The length of lay of the twisted conductors or groups is not specified. A barrier layer, if employed, may be of fibrous wrap serving, or braid; paper; nylon; oriented polyethylene terephthalate; or thermoplastic-type wrap. Such a barrier layer would serve to protect the cable during further processing and would be applied immediately over the twisted assembly of individual conductors or groups of conductors.
ShieldOptional.
JacketExtruded FEP
dia of the cable under jacket in inches
0.425 or less25 mils min average20 mils minimum at any point
0.426-0.700 dia30 avg24 min
0.701-1.500 dia45 avg36 min
1.501-2.500 dia60 avg48 min
2.501 dia and larger80 avg64 min
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseExternal wiring