Rating | 200 deg C, no voltage assigned, Cable flame. Optional - 80 deg C Oil. |
|
Insulated Conductor | Labeled or complying with manufacturer's AWM procedure. |
|
Assembly | Two or more individually insulated conductors or groups of insulated conductors cabled together. All conductors in any group twisted together. If more than one group is used, groups shall also be twisted together. The length of lay of the twisted conductors or groups is not specified. A barrier layer, if employed, may be of fibrous wrap serving, or braid; paper; nylon (polyamide); oriented polyethylene terephthalate; or thermoplastic-type wrap. Such a barrier layer would serve to protect the cable during further processing and would be applied immediately over the twisted assembly of individual conductors or groups of conductors. |
|
Shield | Optional. |
|
Jacket | Extruded FEP. |
| Diameter of the cable under jacket | Minimum average thickenss | Minimum thickness at any point |
| 0.425 inch or less | 25 mils | 20 mils |
| 0.426-0.700 inch | 30 mils | 24 mils |
| 0.701-1.500 mils | 45 mils | 36 mils |
| 1.501-2.500 mils | 60 mils | 48 mils |
| 2.501 inch and larger | 80 mils | 64 mils |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | Internal or external wiring. |
|