			| Rating | 60 deg C, 30 Vac, Cable flame for Use No. 1B and 2B, Horizontal flame for Use No. 1A and 2A. | 
		
			 | 
		
			| Conductor | 40 AWG minimum. Material not specified. | 
		
			 | 
		
			| Insulation | Material not specified for Use Statement No. 1A or 1B.  Labeled or complies with manufacturer's Procedure for Use Statement No. 2A or 2B. | 
		
			 | 
		
			| Assembly | Consists of subunits laid in parallel.  Each subunit composed of two or more singles or groups of insulated singles twisted together, lay not specified, with barrier layer, fillers, shield and/or covering optional. Maximum diameter of subunit 1.0 inch, maximum width of assembly 10.0 inches.  Manufacturer shall maintain a complete description of each assembly. | 
		
			 | 
		
			| Covering | Optional, PVC, 5 mils minimum at any point. | 
		
			 | 
		
			| Shield | Optional, over one or more of the insulated conductors or applied over the assembly. | 
		
			 | 
		
			| Jacket | PVC. | 
		
			 | Diameter of cable under jacket | Minimum average | Minimum at any point | 
		
			 | 0.250 inch or less | 15 mils | 12 mils | 
		
			 | 0.251-0.424 inch | 30 mils | 24 mils | 
		
			 | 0.425-0.700 inch | 60 mils | 48 mils | 
		
			 | 0.701-1.000 inch | 80 mils | 64 mils | 
		
			 | Above thickness is before ripping. | 
		
			 | 
		
			| Standard | Appliance Wiring Material UL 758. | 
		
			 | 
		
			| Marking | General. | 
		
			 | 
		
			| Use | Use No. 1A - Internal wiring in Class 2 circuits of electronic equipment where each end is terminated in connectors. or Use No. 1B - Cables using 30 mils or greater jacket thickness only: external interconnection or internal wiring in Class 2 circuits of electronic equipment where each end is terminated in connectors.  Use No. 2A - Internal wiring in Class 2 circuits of electronic equipment or external interconnection in Class 2 circuits of electronic equipment where not routed along walls, floors, or other abuse areas. or Use No. 2B - Cables using 30 mils or greater jacket thickness only: external interconnection or internal wiring in Class 2 circuits of electronic equipment. | 
		
			 |