APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 20513 Issued:1987-01-06
Revised:2012-03-21
Style 20513 Multiple-Conductor Cable Using Extruded Non-Integral Jacket

Rating80 deg C, 30 Vac, Cable flame.
InsulationLabeled or complying with the manufacturer's AWM procedure
AssemblyThe cable consists of two or three groups of insulated conductors (lay of individual conductors not specified). The groups are laid parallel with an overall PVC jacket and may have an interconnecting web.
ShieldOptional.
JacketExtruded PVC, 30 mils minimum average thickness, 24 mils minimum thickness at any point. Width or thickness of web not specified. Maximum Inner Diameter of core 0.700 inch.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring or external interconnection of electronic equipment in Class 2 or 3 circuits.