APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 20951 Issued:1997-03-05
Revised:2012-12-11
Style 20951 Multiple-conductor cable using non-integral jacket.

Rating105 deg C, 300 Vac, Cable flame.
InsulationLabeled or complying with manufacturer's AWM Procedure. The designations of all styles of individual conductors used in making up the cable assembly shall be available.
AssemblyTwo or more individually insulated conductors or groups of insulated conductors cabled together to form a round cable. A flat or oval cable may also be constructed with not more than three rows of single conductors or groups of conductors. The length of lay of the twisted conductors or groups is not specified. Fillers may be used in a cable but are not required. A barrier layer, if employed, may be a fibrous wrap serving, or braid; paper; nylon; oriented polyethylene terephthalate; or thermoplastic tape wrap. The barrier may be applied over the twisted assembly of individual conductors, groups of conductors or individual conductors.
ShieldOptional.
JacketExtruded TPU.
*Dia of Cable Under Jackt - inMin Avg Thickness - milsMin Thickness At Any Point - mils
1.000 or less4536
1.001-1.5006048
1.501-2.5008064
2.501-4.00011088
4.001 dia and larger140112
* Major dia if cable is flat or oval.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseExternal interconnection of electronic equipment.