APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 20952 Issued:1997-03-05
Revised:2019-11-07
Style 20952 Multiple-conductor cable using non-integral jacket.

Rating105 deg C, 600 Vac, Cable flame.
Conductor36 AWG minimum, solid or stranded.
InsulationLabeled or complying with manufacturer's AWM Procedure.
AssemblyTwo or more individually insulated conductors or groups of insulated conductors cabled together to form a round cable. A flat or oval cable may also be constructed with not more than three rows of single conductors or groups of conductors. The length of lay of the twisted conductors or groups is not specified. Fillers may be used in a cable but are not required. A barrier layer, if employed, may be a fibrous wrap serving, or braid; paper; nylon (polyamide); PET; or thermoplastic tape wrap. The barrier may be applied over the twisted assembly of individual conductors, groups of conductors or individual conductors.
ShieldOptional.
JacketExtruded TPU
major dia. in inches
0.700 or less45 mils min average36 mils minimum at any point
0.701-1.00 dia60 avg48 min
1.001-1.500 dia80 avg64 min
1.501-2.500 dia110 avg88 min
2.501 dia and larger140 avg112 min
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseExternal interconnection of electronic equipment.

UL and the UL Logo are trademarks of UL LLC © 2024