APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 21149 Issued:2001-06-29
Revised:2011-09-16
Style 21149 Multiconductor Cable with Extruded Non-Integral Jacket

Rating60, 80, 90, or 105 deg C, 30 Vac, Horizontal flame.
InsulationLabeled or complying with Manufacturer's Procedure.
AssemblyConsists of a Ribbon Cable folded or spiraled layers or shielded pairs. Section may be slit into singles of 2 to 100 inches in length. Fillers optional. Singles, twisted pairs or groups of singles may be cabled with the ribbon cable.
ShieldOptional.
JacketExtruded PVC
Diameter of core assembly under jacketMinimum average thicknessMinimum thickness at any point
0.700 inch or less10 mils8 mils
0.701-1.000 inch20 mils16 mils
1.001-1.500 inch30 mils24 mils
1.501-2.500 inch45 mils36 mils
2.501-4.000 inch60 mils48 mils
4.001 inch and larger80 mils64 mils
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring.

UL and the UL Logo are trademarks of UL LLC © 2024