| Rating | 80 deg C, 300 Vac, Horizontal flame. |
|
| Conductor | 32 AWG minimum, solid or stranded. |
|
| Insulation | Labeled or complying with Manufacturer's AWM Procedure. |
|
| Assembly | Consists of two or more conductors, twisted pairs or groups of twisted conductors twisted together. The conductors or groups of conductors may be laid parallel forming a flat, oval or round cable. The lay of the conductor is not specified. A barrier layer and/or fillers are optional. Manufacturer shall maintain a complete description of each assembly. May use same or mixed AWG size. |
|
| Shield | Optional. |
|
| Covering | Optional. A 6 mils or heavier covering may be extruded over the conductor assembly. |
|
| Jacket | Extruded TPU, 30 mils minimum average, 24 mils minimum at any point. |
|
| Standard | Appliance Wiring Material UL 758. |
|
| Marking | General. |
|
| Use | Internal wiring of electronic equipment and appliances. Tags may indicate the following: "600 volts Peak for Electronic use only." |
|