Rating | 60 deg C, 30 Vac, Cable flame. |
|
Insulation | Labeled or complying with manufacturer's AWM Procedure. |
|
Assembly | Two or more insulated conductors. |
|
Covering | Optional. |
|
Shield | Optional. |
|
Jacket | Extruded mPPE-PE. For rippable construction, jacket thickness shall be measured after ripping. |
| @ Diameter of core assembly under jacket | Minimum average thickness | Minimum thickness at any point |
| 0.424 inch or less | 30 mils | 24 mils |
| 0.425-0.700 inch | 60 mils | 48 mils |
| 0.701-1.500 inch | 80 mils | 64 mils |
| 1.501-2.500 inch | 110 mils | 88 mils |
| |
| @ Equivalent diameter of flat assembly = 1.1284 x (TW)^0.5 where T is the thickness of the assembly under jacket, and W is the width of the assembly under jacket. |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | External wiring. |
|