APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 21924 Issued:2013-08-29
Revised:New
Style 21924 Multi-conductor cable with non-integral jacket.

Rating105 deg C, 300 Vac, Horizontal flame.
InsulationLabeled or complying with manufacturer's AWM Procedure.
AssemblyTwo or more individually insulated conductors or groups of insulated conductors cabled together to form a round cable. A flat or oval cable may also be constructed with not more than three rows of single conductors or groups of conductors. The length of lay of the twisted conductors or groups is not specified. Fillers may be used in a cable but are not required. A barrier layer, if employed, may be of fibrous wrap serving, or braid; paper; nylon; oriented polyethylene terephthalate; or thermoplastic-type wrap. Such a barrier layer would serve to protect the cable during further processing and would be applied immediately over the twisted assembly of individual conductors or groups of conductors.
ShieldOptional.
CoveringOptional.
JacketExtruded TPU with minimum average thickness 15 mils minimum thickness at any point 12 mils.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal Wiring.

UL and the UL Logo are trademarks of UL LLC © 2024