			| Rating | 80 deg C, Voltage not specified, Cable flame. | 
			|  | 
			| Conductor | Minimum 30 AWG, stranded. | 
			|  | 
			| Insulation | Labeled or complying with manufacturer's AWM Procedure and having a minimum temperature of 80°C. | 
			|  | 
			| Assembly | Consists of two or more conductors, twisted pairs or groups of twisted conductors twisted together. The conductors or groups of conductors may be laid parallel forming a flat, oval or round cable. The lay of the conductor is not specified.  A barrier layer and/or fillers are optional. Manufacturer shall maintain a complete description of each assembly. May use same or mixed AWG size. | 
			|  | 
			| Covering | Optional - Extruded PVC, 6 mils minimum average thickness, may be applied over the conductor assembly. | 
			|  | 
			| Shield | Optional. | 
			|  | 
			| Jacket | Extruded PVC | 
			|  | Diameter of core assembly under jacket | Minimum average thickness | Minimum thickness at any point | 
			|  | 2.50l and larger | 140 mils | 112 mils | 
			|  | 
			| Standard | Appliance Wiring Material UL 758. | 
			|  | 
			| Marking | General. | 
			|  | 
			| Use | External interconnection of computers and electronic equipment. | 
			|  |