Rating | 60 deg C, 30 Vac, Horozontal flame, Cable flame. |
|
Insulated Conductor | 40 AWG minimum. Labeled or complying with Manuacturer's AWM Procedure. |
|
Assembly | Two or more conductors, twisted pairs or groups of twisted conductors twisted together. The conductors or groups of conductors may be laid parallel forming a flat, oval or round cable. The lay of the conductor is not specified. A barrier layer and/or fillers are optional. Manufacturer shall maintain a complete description of each assembly. May use same or mixed AWG size. |
|
Covering | Optional - Extruded PVC, 6 mils minimum thickness. May be extruded over one or more groups of conductors. |
|
Shield | Optional. |
|
Jacket | Extruded PVC. |
| Diameter of core assembly under jacket@ | Minimum average thickness | Minimum thickness at any point |
| 0.701-1.500 inch | 80 mils | 64 mils |
| @ - Major dia if cable is flat or oval. |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | Internal wiring or external interconnection in Class 2 circuits of computers and electronic equipment. |
|