APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 2386 Issued:1964-03-24
Revised:2012-11-05
Style 2386 Multiconductor Cable with Extruded Non-Integral Jacket

Rating60 deg C, 30 Vac, Horozontal flame, Cable flame.
Insulated Conductor40 AWG minimum. Labeled or complying with Manuacturer's AWM Procedure.
AssemblyTwo or more conductors, twisted pairs or groups of twisted conductors twisted together. The conductors or groups of conductors may be laid parallel forming a flat, oval or round cable. The lay of the conductor is not specified. A barrier layer and/or fillers are optional. Manufacturer shall maintain a complete description of each assembly. May use same or mixed AWG size.
CoveringOptional - Extruded PVC, 6 mils minimum thickness. May be extruded over one or more groups of conductors.
ShieldOptional.
JacketExtruded PVC.
Diameter of core assembly under jacket@Minimum average thicknessMinimum thickness at any point
0.701-1.500 inch80 mils64 mils
@ - Major dia if cable is flat or oval.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring or external interconnection in Class 2 circuits of computers and electronic equipment.