APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 2387 Issued:1964-03-24
Revised:2011-10-02
Style 2387 Jacketed Cable.

Rating60 deg C, 30 Vac, Cable flame.
Conductor40 AWG - 10 AWG solid or stranded round, tinned or bare copper.
InsulationLabeled or complying with Manufacturer's AWM Procedure.
AssemblyTwo or more conducts, twisted pairs or groups of twisted conductors twisted together. The conductors or groups of conductors may be laid parallel forming a flat, oval or round cable. The lay of the conductor is not specified. A barrier layer and/or fillers are optional. Manufacturer shall maintain a complete description of each assembly. May use same or mixed AWG size.
ShieldOptional.
Covering(Optional) A 6 mil or heavier PVC covering may be extruded over one or more groups of conductors.
JacketPVC, Dia 1.501-2.500, 110 mils min average, 88 mils minimum at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring or external interconnection in Class 2 circuits of computers and electronic equipment.

UL and the UL Logo are trademarks of UL LLC © 2024