Rating | 150 deg C, 600 Vac, Horizontal flame, Oil Resistant 80 deg C (optional). |
|
Insulation | Labeled or complying with manufacturer's AWM Procedure. |
|
Assembly | Two or more individually insulated conductors or groups of insulated conductors cabled together. All conductors in any group twisted together. If more than one group is used, groups shall also be twisted together. A barrier layer, if employed, may be a fibrous wrap serving, or braid; paper; nylon; oriented polyethylene terephthalate; or thermoplastic-tape wrap. Such a barrier would serve to protect the cable during further processing and would be applied immediately over the twisted assembly of individual conductors or groups of conductors. |
|
Shield | Optional. |
|
Jacket | Extruded FEP; |
| cable dia in inches |
| 0.425 or less | 20 mils minimum average thickness | 18 mils minimum thickness at any point |
| 0.426-0.700 dia | 30 avg | 26 min |
| 0.701-1.500 dia | 45 avg | 40 min |
| 1.501-2.500 dia | 60 avg. 55 min |
| 2.501 dia and larger | 90 avg | 82 min. |
| |
| - Major dia if cable is flat or oval. |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | Internal wiring. The tag may also indicate 2500 volts peak - For Electronic Use Only. |
|