Rating | 200 deg C, 300 Vac, Horizontal flame, 80 deg C Oil. Optional - Oil Resistant. |
|
Insulation | Labeled or complying with manufacturer's AWM Procedure. |
|
Assembly | Two or more individually insulated conductors or groups of insulated conductors cabled together. All conductors in any group twisted together. If more than one group is used, groups shall also be twisted together. The length of lay of the twisted conductors or groups is not specified. A barrier layer, if employed, may be a fibrous wrap serving, or braid; paper; nylon; PET; or thermoplastic-tape wrap. Such a barrier would serve to protect the cable during further processing and would be applied immediately over the twisted assembly or individual conductors or groups of conductors. |
|
Shield | Optional. |
|
Jacket | FEP |
| Dia of cable under jacket in inches | Minimum average thickness in mils | Minimum thickness at any point in mils |
| 0.425 or less | 20 | 18 |
| 0.426-0.700 | 30 | 26 |
| 0.701-1.500 | 45 | 40 |
| 1.501-2.500 | 60 | 55 |
| 2.501 and larger | 90 | 82 |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | Internal wiring of appliances or electronic equipment. |
|