			| Rating | 60 deg C, 30 Vac, Cable flame. | 
		
			 | 
		
			| Insulated Conductor | Labeled or complies with this Manufacturers AWM singles Procedure. | 
		
			 | 
		
			| Assembly | Two or more insulated singles or groups of insulated singles cabled together to form a flat, oval or round assembly. Barrier layer and/or fillers optional. May use same or mixed AWG size. Manufacturer shall maintain a complete description of each assembly. | 
		
			 | 
		
			| Covering | Optional, extruded PVC, 5 mils minimum thickness at any point, over the conductor assembly or extruded PTFE, PFA, FEP or ETFE, 8 mils minimum average thickness, 6 mils minimum thickness at any point. | 
		
			 | 
		
			| Shield | Optional. | 
		
			 | 
		
			| Covering | Optional, extruded PVC, 5 mils minimum thickness at any point, over the conductor assembly or extruded PTFE, PFA, FEP or ETFE, 8 mils minimum average thickness, 6 mils minimum thickness at any point. | 
		
			 | 
		
			| Shield | Optional. | 
		
			 | 
		
			| Jacket | Extruded PVC. | 
		
			 | Major diameter of assembly under jacket* | Minimum average thickness | Minimum thickness at any point | 
		
			 | 0.700 inch or less | 30 mils | 24 mils | 
		
			 | 0.701-1.000 inch | 45 mils | 36 mils | 
		
			 | 1.001-1.500 inch | 60 mils | 48 mils | 
		
			 | 1.501-2.500 inch | 80 mils | 64 mils | 
		
			 | 2.501-4.000 inch | 110 mils | 88 mils | 
		
			 | 4.001 inch or larger | 140 mil | 112 mils | 
		
			 | * - Major diameter if cable is flat or oval. | 
		
			 | 
		
			| Standard | Appliance Wiring Material UL 758. | 
		
			 | 
		
			| Marking | General. | 
		
			 | 
		
			| Use | Internal Wiring and External Interconnection in Class 2 Circuits of Electronic Equipment. | 
		
			 |