APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 2842 Issued:1976-12-27
Revised:2012-02-24
Style 2842 Multiple-conductor cable using non-integral jacket.

Rating80 deg C, 30 Vac, Cable flame.
Insulated Conductor40 AWG minimum - Labeled or complying with Manufacturer's AWM Procedure having a minimum rating of 80 deg C.
AssemblyTwo or more twisted singles or groups of twisted singles cabled together to form a flat or round cable with no more than three rows of single conductors or groups of conductors. Lay not specified. Barrier layer and/or fillers optional. Manufacturer shall maintain a complete description of each assembly.
ShieldOptional.
JacketExtruded PVC
Diameter of core assembly under jacketMinimum average thicknessMinimum thickness at any point
1.0 inch or less45 mils36 mils
1.001-1.500 inch60 mils48 mils
1.501-2.500 inch80 mils64 mils
2.501-4.000 inch110 mils88 mils
4.001 inch or larger140 mils112 mils
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseExternal Interconnection in Class 2 circuits of Electronic Equipment where each end is terminated in connectors.

UL and the UL Logo are trademarks of UL LLC © 2024