| Rating | 150 deg C, 600 Vac, Horizontal flame. |
|
| Conductor | 8 AWG - 4/0 AWG. |
|
| Insulation | Extruded SR |
| Conductor size | Minimum average thickness | Minimum thickness at any point |
| 8-2 AWG | 60 mils | 54 mils |
| 1-4/0 AWG | 80 mils | 72 mils |
|
| Covering | Same as for Type SF-2 Fixture Wire. |
|
| Standard | Appliance Wiring Material UL 758. |
|
| Marking | General. |
|
| Use | Internal Wiring of Appliances (such as Heating Appliances and Lighting Fixtures). |
|