APPLIANCE WIRING MATERIAL
Subj.758 Section 3 Page 3519 Issued:1988-10-04
Revised:2011-11-09
Style 3519 Insulated Wire

Rating200 deg C, 600 Vac, Horizontal flame.
Conductor22 AWG - 12 AWG, solid or stranded.
InsulationSilicone rubber, 30 mils minimum average, 27 mils minimum at any point.
CoveringExtruded FEP, 2 mils minimum at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal Wiring of Appliances where not subjected to mechanical abuse.