APPLIANCE WIRING MATERIAL
Subj.758 Section 3 Page 3645 Issued:2000-05-18
Revised:2011-10-11
Style 3645 Single conductor with extruded insulation and covering

Rating150 or 200 deg C, 1000 Vac, Horizontal flame.
Conductor30 AWG - 750 kcmil, solid or stranded.
InsulationExtruded SR
Conductor SizeMin averageMin at any point
30-10 AWG45 mils40 mils
8-2 AWG60 mils54 mils
1-4/0 AWG80 mils72 mils
250-500 kcmil95 mils85 mils
501-750 kcmil110 mils99 mils
CoveringExtruded SR, or acrylic based emulsion finished polyaramid or glass braid.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal Wiring of Appliances or Electronic Equipment.