| Rating | 200 deg C, 600 Vac, Horizontal flame. |
|
| Conductor | 24 AWG - 14 AWG solid or stranded round. |
|
| Insulation | PTFE, TFE, 17 mils min average, 15 mils minimum at any point. |
|
| Assembly | TFE tape applied in two wraps minimum at any point of 17 mils, with an overall impregnated glass braid. |
|
| Standard | Appliance Wiring Material UL 758. |
|
| Marking | General. |
|
| Use | In heating cable assemblies where the acceptability of the combination is to be determined by Underwriters Laboratories Inc. |
|