APPLIANCE WIRING MATERIAL
Subj.758 Section 1 Page 10003 Issued:1987-03-13
Revised:2012-11-12
Style 10003 Single conductor with other-than-extruded insulation

Rating105 deg C, 30 Vac, Horizontal flame.
Conductor40 AWG minimum, solid or stranded.
InsulationPolyimide film with Polyester Adhesive, 2 mils minimum average thickness, 1.0 mil minimum thickness at any point.
AssemblyTwo insulated conductors may be twisted together. Assembly together
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal Wiring of Class 2 Circuits in Electronic Equipment.

UL and the UL Logo are trademarks of UL LLC © 2025