APPLIANCE WIRING MATERIAL
Subj.758 Section 1 Page 10005 Issued:1986-12-29
Revised:2013-01-28
Style 10005 Single conductor with other-than-extruded jacket or non-integral jacket.

Rating80 deg C, 30 Vac, Horizontal flame.
Conductor50 AWG minimum, solid or stranded.
InsulationInner layer: Extruded PTFE, extruded PFA, extruded FEP, extruded foamed PE, extruded PE, extruded XLPTFE, extruded XLPFA, extruded XLFEP, extruded foamed XLPE or extruded XLPE, 2 mils minimum thickness at any point; or foamed PTFE tape wrap, one or more layers, overall insulation thickness 2 mils minimum at any point. Outer layer: (Optional) Polyester tape, overall thickness 0.2 mils minimum thickness at any point and heat sealed.
ShieldOptional.
JacketInner jacket - Spirally wrapped, two or more layers of polyester, ETFE, PTFE, foamed PTFE, or composite tape, and heat sealed, overall thickness minimum 0.2 mils at any point, or extruded PFA, extruded FEP, or extruded PVDF, 1 mil minimum at any point.
ShieldOptional.
JacketOptional, outer jacket, same as inner jacket.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring.

UL and the UL Logo are trademarks of UL LLC © 2024