Rating | 90 deg C, 30 Vac, Horizontal Flame. |
|
Conductor | 40-20 AWG, Solid or Stranded Round. Material not specified. |
|
Insulation | Extruded PTFE, Extruded PFA or Extruded FEP, 3.5 mils minimum average, 3.0 mils minimum at any point; or extruded foamed PFA or extruded foamed FEP, 4 mils minimum average, 3.5 mils minimum at any point; or tape wrapped Non-Extruded PTFE, 3.5 mils minimum average, 3.0 mils minimum at any point; or tape wrapped foamed Non-Extruded PTFE, 4.0 mils minimum average, 3.5 mils minimum at any point. Tape wrap may be one or more layers minimum 30 percent overlap of at least one layer. |
|
Assembly | Insulated conductor with optional inner covering, optional inner shield, optional outer covering, optional outer shield and optional jacket. |
|
Inner Covering | Optional
(1) Extruded PTFE, Extruded PFA, Extruded FEP, Extruded ETFE, or tape wrapped Non-Extruded PTFE, 1 mil minimum at any point, or
(2) Tape wrapped Non-Extruded "Milene" (polyester or PVC adhesives on PET) 0.2 mil minimum at any point. |
|
Inner Shield | Optional. |
|
Outer Covering | Optional
(1) Extruded PTFE, Extruded PFA, Extruded FEP, Extruded ETFE, or tape wrapped Non-Extruded PTFE, 1 mil minimum at any point, or
(2) Tape wrapped Non-Extruded "Milene" (polyester or PVC adhesives on PET) 0.2 mil minimum at any point. |
|
Outer Shield | Optional. |
|
Jacket | Optional
(1) Extruded PTFE, Extruded PFA, Extruded FEP, Extruded ETFE, Extruded PVC 1.5 mils minimum thickness, or
(2) Tape wrapped Non-Extruded PTFE 1 mil minimum thickness, or
(3) Tape wrapped Non-Extruded "Milene" 0.2 mil minimum thickness. |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | Internal wiring of Class 2 circuits in electrical equipment or as insulated single in jacketed multiconductor cables. |
|