APPLIANCE WIRING MATERIAL
Subj.758 Section 1 Page 10025 Issued:1988-05-03
Revised:2012-04-24
Style 10025 Single Conductor with Extruded Insulation

Rating60 deg C, 30 Vac, Horizontal flame.
Conductor40 AWG minimum, material not specified.
InsulationExtruded ETFE or Extruded FEP, 2 mils minimum average thickness at any point, maximum 30 mils.
ShieldOptional.
CoveringExtruded FEP or Extruded ETFE, 3 mils minimum at any point, maximum 30 mils.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring of Class 2 circuits of electronic equipment or as insulated single in jacketed multiconductor or cables.