Subj.758 Section 1 Page 1003 Issued:1959-08-13
Revised:2011-08-22
Style 1003 Single Conductor with Extruded Insulation and Non-Integral Jacket.

Rating60 deg C, 300 Vac, Horizontal flame.
Conductor26 AWG - 16 AWG, solid or stranded.
InsulationExtruded PE or extruded FRPE, 30 mils minimum average thickness, 27 mils minimum thickness at any point.
ShieldOptional.
JacketExtruded PVC, 15 mils minimum average thickness, 13 mils minimum thickness at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring.