APPLIANCE WIRING MATERIAL
Subj.758 Section 1 Page 10032 Issued:1988-07-06
Revised:2012-11-12
Style 10032 Single conductor with other-than-extruded insulation

Rating250 deg C, 600 Vac, Horizontal flame.
Conductor30 AWG - 10 AWG, solid or stranded.
InsulationExtruded PFA, 15 mils minimum average thickness, 13 mils minimum thickness at any point.
CoveringFelted impregnated glass braid, 10 mils minimum average.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal Wiring of Appliances or electronic equipment.