APPLIANCE WIRING MATERIAL
Subj.758 Section 1 Page 10033 Issued:1988-11-09
Revised:2013-02-07
Style 10033 Single conductor with extruded insulation

Rating105 deg C, 600 Vac, Horizontal flame, 75 deg C Wet.
ConductorResistance wire. (Size depends upon wattage demand).
InsulationExtruded ETFE, 12 mils minimum average thickness, 10 mils minimum thickness at any point.
CoveringOptional. Extruded Nylon, 5 mils minimum thickness at any point.
Sensor WireOptional. Uninsulated copper or copper alloy conductor applied as serve wrap or braid, 33 AWG or smaller strands, minimum coverage 80%.
CoveringExtruded Nylon, 10 mils minimum thickness at any point.
JacketOptional. Extruded PVC, 45 mils minimum average thickness, 36 mils minimum thickness at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring.

UL and the UL Logo are trademarks of UL LLC © 2024