Rating | 80 deg C, voltage not specified, Horizontal flame. Optional - 60 deg C or 80 deg C Oil. |
|
Conductor | 30 AWG - 16 AWG, solid or stranded. |
|
Insulation | Extruded PVC, 8 mils minimum average thickness, 6 mils minimum thickness at any point. |
|
Covering | Extruded Nylon, 2 mils minimum thickness at any point, or lacquered braid. |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | Internal Wiring of Appliances. |
|