APPLIANCE WIRING MATERIAL
Subj.758 Section 1 Page 10041 Issued:1989-01-06
Revised:2012-07-14
Style 10041 Single conductor with extruded insulation

Rating60 deg C, 300 Vac, Horizontal flame.
Conductor30 AWG - 16 AWG solid or stranded round, tinned or bare, copper or copper alloy.
InsulationXLPE, 23 mils min average, 21 mils minimum at any point.
AssemblyInsulated conductor with optional covering, optional inner shielding, inner jacket, optional outer shield and optional outer jacket.
ShieldBoth inner and outer shield are Optional.
CoveringOptional. PVC, Polyamide, or Polyester, 2 mils min or lacquered braid.
JacketInner - PVC, 15 mils min average, 12 mils minimum at any point. Outer - same as inner except is optional.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring of Electronic Equipment.

UL and the UL Logo are trademarks of UL LLC © 2024