Style 10043 Single-Conductor using Non-Integral Extruded Jacket.

Rating80 deg C, 30 Vac, Cable Flame.
Conductor40 AWG minimum, Solid or Stranded Round.
InsulationLabeled or complying with Manufacturer's AWM Procedure.
CoveringOptional, extruded over the conductor assembly.
ShieldOptional.
JacketExtruded PVC.
Construction AConstruction B
Dia of cable under jacket in inchesMinimum average in milsMinimum at any point in milsMinimum average in milsMinimum at any point in mils
0.350 inch or less20161512
0.351-0.70030243024
0.701-1.00040324032
1.001-1.50054435443
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseConstruction A: Internal Wiring or External Interconnection of Electronic Equipment in Class 2 circuits only. Construction B: Internal Wiring of Electronic Equipment in Class 2 circuits only.