APPLIANCE WIRING MATERIAL
Subj.758 Section 1 Page 10051 Issued:1989-03-03
Revised:2012-07-20
Style 10051 Single Conductor using Non-Integral Extruded Jacket

Rating60 or 80 deg C, 30 Vac, Cable Flame.
Conductor40 AWG minimum, Solid or Stranded Round, material not specified.
InsulationSolid or Foamed, Extruded FEP or Extruded PFA or Extruded PTFE, 10 mils minimum at any point, 60 mils maximum.
AssemblyInsulated conductor with optional inner shield, covering, optional outer shield and jacket.
Inner ShieldOptional.
CoveringExtruded PVC, Extruded PFA, Extruded FEP or Extruded PTFE, 8 mils minimum at any point.
Outer ShieldOptional.
JacketExtruded PVC, 30 mils min average, 24 mils minimum at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseExternal interconnection or internal wiring of electronic equipment.

UL and the UL Logo are trademarks of UL LLC © 2024