APPLIANCE WIRING MATERIAL
Subj.758 Section 1 Page 10058 Issued:1989-04-26
Revised:2012-03-29
Style 10058 Multiple-Conductor Cable Using Extruded Non-Integral Jacket

Rating150, 200 deg C, 300 Vac, Horizontal flame.
Conductor30 AWG - 16 AWG stranded, plated.
InsulationExtruded PTFE, TFE, 14 mils minimum average thickness, 13 mils minimum thickness at any point.
ShieldOptional.
JacketExtruded FEP, 10 mils minimum average thickness, 8 mils minimum thickness at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring of Electronic Equipment.

UL and the UL Logo are trademarks of UL LLC © 2024