APPLIANCE WIRING MATERIAL
Subj.758 Section 1 Page 10063 Issued:1989-06-09
Revised:2012-04-09
Style 10063 Single conductor with extruded insulation.

Rating80 deg C, 300 Vac.
Conductor32 AWG - 16 AWG, solid or stranded.
InsulationExtruded PE or extruded FRPE, 13 mils minimum average thickness, 12 mils minimum thickness at any point.
CoveringOptional - A 3 mils minimum thickness at any point or heavier covering of PVC may be extruded over the insulation.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseFor further processing into cables.