APPLIANCE WIRING MATERIAL
Subj.758 Section 1 Page 10065 Issued:1989-07-24
Revised:2013-11-28
Style 10065 Single conductor with extruded insulation

Rating80 deg C, 90 Vac, Horizontal flame.
Conductor50 AWG minimum. Material and stranding not specified.
InsulationExtruded PVC, extruded foamed PVC, extruded SRPVC, extruded XLPVC, extruded foamed XLPVC or extruded XLSRPVC, 3 mils minimum thickness at any point, 100 mils maximum.
CoveringOptional. Extruded PVC, extruded Nylon (Polyamide), extruded ETFE, extruded Polyester, extruded XLPVC, extruded XL Nylon, extruded XLETFE or extruded XL Polyester, 2 mils minimum thickness at any point, or lacquered braid.
ShieldOptional.
JacketOptional. Same as covering.
ShieldOptional.
CoveringOptional. Same as covering.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring of Electronic Equipment.

UL and the UL Logo are trademarks of UL LLC © 2024