APPLIANCE WIRING MATERIAL
Subj.758 Section 1 Page 10081 Issued:1990-06-29
Revised:2012-07-20
Style 10081 Single Conductor using Non-Integral Extruded Jacket

Rating105 deg C, 30 Vac, VW-1 Flame.
Conductor40 AWG minimum, Solid or Stranded Round, material not specified.
InsulationSolid or Foamed, Extruded PE or Extruded XLPE or Extruded FRPE or Extruded XLFRPE, 4 mils minimum at any point.
AssemblyInsulated conductor with optional inner covering, optional inner shield, jacket, optional outer shield and optioal outer covering.
Inner CoveringOptional - 2 mils minimum at any point Extruded PVC, Extruded Nylon, Extruded Polyester, Extruded PVDF, Extruded ETFE, Extruded XLPE or Extruded XLFRPE, or Non-Extruded lacquered braids.
Inner ShieldOptional.
JacketExtruded PVC, 5 mils minimum average, 3 mils minimum at any point.
Outer ShieldOptional.
Outer CoveringOptional - Extruded PVC, 5 mils minimum at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseWiring of low energy non-hazardous circuits in audio and video equipment.

UL and the UL Logo are trademarks of UL LLC © 2024