APPLIANCE WIRING MATERIAL
Subj.758 Section 1 Page 10103 Issued:1991-08-14
Revised:2012-07-13
Style 10103 Single conductor with extruded insulation

Rating80 deg C, 125 Vac, Horizontal flame.
Conductor30 AWG - 16 AWG solid or stranded round, tinned or bare copper or solid untinned copper clad steel.
InsulationPE, Inner layer - Cellular polyethylene. Outer layer - Solid polyethylene. Composite thickness 15 mils minimum, average thickness, 13 mils minimum thickness at any point, 100 mils maximum average thickness. (Two layers are non-separable). May be irradiated.
AssemblyInsulated conductor with optional inner shield, optional inner covering, optional outer shield and optional outer covering.
ShieldEither Inner shield or outer shield must be present.
CoveringEither Inner covering or outer covering must be present. Extruded PVC, minimum average thickness 10 mils, minimum thickness at any point 8 mils.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring of Electronic Equipment.

UL and the UL Logo are trademarks of UL LLC © 2024