APPLIANCE WIRING MATERIAL
Subj.758 Section 1 Page 10106 Issued:1991-08-29
Revised:2012-07-09
Style 10106 Single Conductor with Extruded Insulation.

Rating60, 80, or 90 deg C, 300 Vac.
Conductor36 AWG - 9 AWG solid or stranded round.
InsulationExtruded TPE
36-18 AWG conductor size9 mils min average7 mils min at any point
17-15 AWG12 avg10 min
14-9 AWG17 avg15 min
See Facing Page for Compound.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseAs insulated singles in external interconnection wires and cable for electronic equipment. Tag may also indicate the following: "600 V Peak - For Electronic Use Only."

UL and the UL Logo are trademarks of UL LLC © 2024