APPLIANCE WIRING MATERIAL
Subj.758 Section 1 Page 10107 Issued:1991-09-11
Revised:2012-11-05
Style 10107 Single-conductor cable using non-integral jacket

Rating80, 90, or 105 deg C, 600 Vac, FT2 flame.
Insulated Conductor30 AWG - 750 kcmil, solid or stranded. Labeled or complying with the manufacturer's AWM procedure. Extruded PVC insulation.
Conductor sizeMinimum average insulation thicknessMinimum insulation thickness at any point
30-16 AWG20 mils18 mils
14-10 AWG32 mils28 mils
8-4 AWG46 mils40 mils
2-3/0 AWG56 mils50 mils
4/0 AWG-300 kcmil70 mils62 mils
350-500 kcmil86 mils76 mils
500-750 kcmil110 mils99 mils
ShieldOptional.
JacketExtruded PVC.
Diameter of core assembly under jacketMinimum average thicknessMinimum thickness at any point
0.425 inch or less45 mils36 mils
0.426-0.700 inch60 mils48 mils
0.701-1.500 inch80 mils64 mils
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring or external interconnection of electronic equipment.

UL and the UL Logo are trademarks of UL LLC © 2024