APPLIANCE WIRING MATERIAL
Subj.758 Section 1 Page 10119 Issued:1992-01-22
Revised:2012-03-30
Style 10119 Single-Conductor Cable Using Extruded Non-Integral Jacket

Rating80 deg C, 300 Vac, VW-1 flame.
Conductor7 AWG solid, tinned or bare.
InsulationExtruded Foamed FRPE, 66 mils minimum average thickness, 59 mils minimum thickness at any point, maximum thickness 120 mils.
ShieldTinned or bare copper sheath, 10 mils minimum thickness.
JacketExtruded PVC, 35 mils minimum average thickness, 28 mils minimum thickness at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseVW-1 Rated internal or external interconnection of electronic equipment or appliances.

UL and the UL Logo are trademarks of UL LLC © 2024